Latest current version: 2024.11.1 19.11.2024

If version is not in the list, it means that update was done for technical reasons and does not contain any critical changes.

Reset

Version 2024.11.1 19.11.2024

Improvements:

  • Added the ability to search for a server by ID in the “Assemble/disassemble server” form.
  • Increased performance of API queries and platform database queries.

Bug fixes:

  • Fixed an error that caused components extracted from the server to have an incorrect status in the warehouse.
  • Fixed an error that caused a user to not have a note displayed in a minimized server card.
  • Fixed an error that caused the indication of components not detected during diagnostics not to be displayed.
  • Fixed an error that caused the filter drop-down menu in the VLAN table to change position when filters were applied.
  • Fixed an error where clicking on the branded logo would not open the locations page.

Version 2024.10.1 22.10.2024

Improvements:

  • Added notification of the total number of server errors found as a result of diagnostics.
  • Added support for mounting ISO images via the Redfish protocol for HPE ProLiant Gen10 and Lenovo servers.
  • Added the ability to batch poll equipment in switch and PDU tables.
  • In the “Disassemble” subsection, added automatic detection of the warehouse to which the server belongs.
  • Added the ability to specify for ISO images the user groups for which they will be available.

Bug fixes:

  • Fixed the error that caused RAID 0 partition sizes to differ from the specified sizes when installing the OS on the server.
  • Fixed incorrect filtering of IP addresses by “Errors” status in the server card.
  • Fixed a bug that made it impossible to enter your values in select-type fields when editing user parameters.
  • Fixed the error that made it impossible to resize a platform even if there were no servers with that platform in operation.
  • Fixed the error that caused every error found on a server to duplicate that server in the list.
  • Fixed the error 1111 on opening the “Synchronization with LDAP” menu for the first time.

Version 2024.09.1 24.09.2024

New features:

  • Added support for Brocade ICX 6450-48 switch (IronWare Version 08.0.30pT311).
  • Added the option to manage platform SSL certificates and issue a free Let's Encrypt certificate. More details in the documentation: https://ispsystem.com/docs/x/toW4Ag

Improvements:

  • Added the option to configure basic UEFI/BIOS parameters in the server card. More details in the documentation: https://ispsystem.com/docs/x/SQFEDw
  • Added support for managing Graviton servers with URAL motherboards using Redfish and IPMI protocols and with VALDAY motherboards using IPMI protocol.
  • Unified the mechanism of interaction with entities in the server table in DCImanager and VMmanager products. Added the option to enter the server card by double-clicking.

Bug fixes:

  • Fixed an error that made it impossible to change the NetConf port in the switch settings.
  • Fixed the error that caused the web interface to not be available after upgrading the platform from older versions.

Version 2024.08.1 28.08.2024

New features:

Improvements:

  • Added the ability to enter an arbitrary value in the “Alias for configuration” field when creating and editing a drive in the Inventory management profile.
  • The size of the boot partition for the Linux family of operating systems in the default partitioning is increased from 256 to 512 MB.

Bug fixes:

  • Fixed the error that caused components from the “Other equipment” section to fall into the “Power supplies” section when added to the server.
  • Fixed the error that made it impossible to move servers between warehouses.
  • Fixed the error that made it impossible to change the accounting statuses of servers in the warehouse.
  • Fixed a bug that caused BMC users whose creation failed to complete to not be updated.

Version 2024.07.2 30.07.2024

New features:

  • Added Security policies section to the global settings menu to customize user authentication.

Improvements:

  • Increased platform's maximum number of RAM slots from 64 to 128.
  • Added column with BMC status to the servers table.
  • Added information on the equipment addition date to the Inventory management section.
  • Added periodic update of license information to the platform services cache.

Bug fixes:

  • Fixed the error that made it impossible to run server group diagnostics without an OS template loaded.
  • Fixed the error that caused the server table to not display notes.
  • Fixed the error that made it impossible to add localization to WIndows family OS using $LANG macro.

Version 2024.07.1 02.07.2024

New features:

  • Added the ability to reboot server BMC.

Improvements:

  • Added support for APC Smart-UPS SRT 10000 UPS via SNMP.
  • Added support for managing Cisco UCS C240 M4SX servers via Redfish and IPMI protocols.
  • Added display of RAID and LAN controller information to the server card.

Bug fixes:

  • Fixed the error that caused the "Disable Traffic Collection" option in the Switch Port Settings form to not work.

Version 2024.06.1 18.06.2024

New features:

  • Added the ability to view and manage active user sessions.
  • Added the ability to send notifications to Telegram messenger. Read more in the documentation: https://docs.ispsystem.com/x/PBN0DQ
  • Added information about the presence of RAID controllers to the full server diagnostics report.
  • Added the option to specify HDD rpm and memory type for SSD when creating and editing a drive model.
  • Added the Ubuntu 24.04 OS installation template.

Improvements:

  • Added the option to obtain MAC addresses on switch ports when polling the equipment using the Cisco Catalyst 45xx (SNMP) handler.
  • Added support for managing servers with ASUS X99 WS/IPMI motherboard via IPMI.
  • Added display of flashing operations to the server history.

Bug fixes:

  • In the form of server connection to BMC, the maximum length of the "Login" field has been increased to 255 characters.
  • Fixed the error that caused the server auto-add settings menu not to be displayed.

Version 2024.05.1 21.05.2024

New features:

  • Added the option to create a firmware repository for server components and perform group flashing of servers.
  • In the VPU module settings, added BGP session support for IPv6 and the option to specify multiple BGP neighbors.
  • WireGuard installation script added.

Improvements:

  • Added support for APC MGE Galaxy 300 40kVA 3:3 UPS via SNMP.
  • Added the Rocky Linux OS installation template.
  • Added an indicator to the server table that displays when Redfish has identified component mismatches in servers as the result of diagnostics or BMC polling.
  • Added the option to manage server behavior after diagnostics is completed.

Bug fixes:

  • Fixed the error that made it impossible to upload an ISO image when connecting to the platform via a proxy server.
  • Fixed the error that could cause the BMC type name to not be displayed after the server diagnostics was completed.
  • Fixed the error that caused BMC log collection to not work if it contained an entry with an incorrect date.
  • Fixed the error that caused the interface to display empty BMC log entries.
  • Fixed the error that occasionally occurred when configuring a location after a platform update.

Version 2024.04.2 23.04.2024

Improvements:

  • Disabled support of the auth v3 authorization service. To configure authorization use the auth v4 service. Read more in the documentation: https://docs.ispsystem.com/x/-LToAQ.
  • Added the option to set the status "In laboratory" for components in the warehouse through the context menu of the table.
  • Improved display of validation errors on the authorization page.
  • Added the option to configure connection to Intel AMT when creating a server.

Version 2024.04.1 09.04.2024

New features:

  • Added the ability to update the component list for servers with BMC Redfish.
  • Added the ability to quickly switch the user interface language.
  • Added Arch Linux OS installation template.

Improvements:

  • Added dynamic update of information from BMC sensors if notifications were created for them.

Version 2024.03.1 26.03.2024

New features:

Improvements:

  • Added time display in the window with information about diagnostics, taking into account the time zone settings.
  • Added support for managing OpenYard HN201I, OpenYard HN201A, OpenYard HN2B7I and OpenYard HN2B7A servers via Redfish.
  • Improved operation of table filters: added selection of filter text by pressing Ctrl+A or Cmd+A.

Bug fixes:

  • Fixed the error that prevented installation of a platform behind a proxy server. Uploading ISO images for such installations is temporarily restricted.
  • Fixed the error that caused zombie processes to remain in the dci_back service.
  • Fixed the error with getting the list of components for HPE Gen10 servers.
  • Fixed an error that caused the server configuration not to be updated after running diagnostics and adding new components.
  • Fixed the problem that could cause a high database load when navigating to the IP address table.
  • Fixed the error with displaying three or more OS groups on the installation form.
  • Fixed an issue that caused network configuration to fail after installing Debian 10, Debian 11 and Debian 12 templates on a server.

Version 2024.02.1 27.02.2024

New features:

  • Changed the display of information about IPv6 networks and pools: instead of the number of occupied addresses, the number of occupied subnets will be displayed.

Improvements:

  • Improved stability of sending notifications about operation errors during server diagnostics.

Bug fixes:

  • Fixed the error that caused the list of pools to be incorrectly displayed on the physical network adding form.
  • Fixed the error that made it impossible to select an IP address pool that had both IPv4 and IPv6 addresses.
  • Fixed the error that caused filtering of servers by status to not work.

Version 2024.01.1 31.01.2024

New features:

  • Added support for Extreme Networks switches with EXOS firmware via HTTP/HTTPS protocol.
  • Added support for Legrand Keor MOD 250 UPS with CS141 SNMP module.

Improvements:

  • Updated the design of the authorization form.
  • Implemented platform log collection using journald service. More details in the documentation: https://docs.ispsystem.com/x/MgAcBw
  • Added automatic display of a window with the progress of ISO image uploading from a local PC.
  • Reduced load on the platform server CPU when updating Intel AMT and PDU statuses.

Version 2023.12.1 21.12.2023

Improvements:

  • Added the option to activate the license within 7 days after restoring the platform from a backup for DCImanager Infrastructure.

Bug fixes:

  • Fixed the problem that caused a new connection to be created when editing an existing switch connection to a server.
  • Fixed the error that made it impossible to view the password in the settings of server connection to BMC.

Version 2023.11.2 29.11.2023

New features:

  • Added the option to create custom equipment parameters through the interface.

Improvements:

  • Added the option to view the entire list of server IP addresses from the server table and rack card.
  • Added the option to create an OS template from a VMware ESXi-7 ISO image. See the documentation for more details: https://docs.ispsystem.com/x/rALeCw
  • Added the option to edit uploaded ISO images.
  • Added the option to increase the platform size for servers and blade servers in a rack or chassis.
  • Added a banner to the locations dashboard page to notify platform administrators. The banner is displayed when there is important news about the product.
  • Changed the format of displaying the time of operations: for each administrator, the time is specified considering the time zone settings.

Bug fixes:

  • Fixed execution of the POST request /ipmiproxy/v3/ipmi/{ipmi_id}/proxy/web via Swagger.
  • Fixed the error that in some cases prevented uploading a large ISO image from a local computer.
  • Added filters by serial number, model, and alias in the add components to server tab.
  • Fixed synchronization with LDAP with a large number of groups and users.
  • Fixed the error that interfered with saving filters for user's custom parameters.
  • Fixed the error that prevented the switch port settings from being saved.
  • Fixed transition to warehouse component settings from the "Components" section of the server card.

Version 2023.11.1 01.11.2023

New features:

  • Added the option to add and remove server components in groups.
  • Added chassis management into the Inventory management module. More information in the documentation: https://docs.ispsystem.com/x/9tG4Ag

Improvements:

  • Links to documentation with possible solutions to the problem have been added to error notifications.
  • Added the option to configure notifications for reserved equipment and equipment under warranty.
  • Added the option to connect the location server using a public SSH key.
  • Updated WHMCS integration module: added support for WHMCS 8.8.0, auth_v4 service is used for authorization instead of auth_v3.
  • Added the option to specify the value "NVME" in the "Alias for configuration" field for drive models.
  • Added display of the disk serial number in the SMART section of the diagnostics results.
  • Added display of additional (custom) fields for chassis.
  • Added the ability to automatically create a BMC server operator when running diagnostics with the "Configure BMC" option. Read more in the documentation: https://docs.ispsystem.com/x/DK3oAQ
  • Added the option of group diagnostics of servers.
  • Added filtering option for NetFlow statistics.

Bug fixes:

  • Fixed the error during switch operations that occurred in some cases after saving the configuration to the device ROM.
  • Added the option to cancel server firmware upload.
  • Fixed the error that caused DNS server addresses not being written to the resolv.conf file when installing an OS from an AlmaLinux 9 template.
  • Fixed IP address allocation to the server when operating with a large number of VPU networks.
  • Added the option to run diagnostics with subsequent server shutdown.
  • Fixed the problem that could cause the location to change when going to the server card.
  • Fixed the problem that made it impossible to configure the DNSmanager 6 integration module.
  • Fixed filtering by BMC address in the servers table.
  • Fixed the error that could cause high CPU load on the location server.

Version 2023.10.1 04.10.2023

New features:

  • Added the option to transfer server logs from BMC Redfish to Grafana in the location settings. More details in the documentation: https://docs.ispsystem.com/x/GgCdCw
  • Added AlmaLinux 9 OS installation template.

Improvements:

  • Updated the design of icons in the main menu.
  • Updated the design of the menu sidebars.
  • Added the ability to use dots in server and blade server platform names.
  • The nginx version has been removed from the web server responses.
  • The option of group operations on devices and components has been added to the Inventory management module.
  • Added saving of comments and changes in them to the server history.
  • Information about the server platform has been added to the information received during server auto-adding via BMC Redfish.

Bug fixes:

  • Fixed the error that prevented a user with restricted access by IP address from adding equipment to operation.
  • Fixed the error that caused a list of all components in the warehouse to open when editing components in the server card.

Version 2023.09.1 06.09.2023

New features:

  • Added the option to update BMC and BIOS/UEFI server firmware in the DCImanager Infrastructure version. More details in the documentation: https://docs.ispsystem.com/x/UrS4Ag

Improvements:

  • The server information is supplemented with the hostname value to identify the server when auto-adding through the Navy via Redfish.
  • The mode of auto-detection of connection type to BMC has been added for server auto-adding.
  • Added the option to specify additional settings for custom PDU handlers. More details in the documentation: https://docs.ispsystem.com/x/y5-oAQ

Bug fixes:

  • Fixed the problem that caused users on a server with IDRAC 8 to be created with IDRAC mode disabled, resulting in the inability to log in as that user.
  • Fixed the error that caused the server card information to not be displayed after configuring the BMC.
  • Fixed the error that caused the server adding form to freeze when trying to use an already busy MAC address.

Version 2023.08.5 30.08.2023

Improvements:

Version 2023.08.4 23.08.2023

Improvements:

  • Improved operation of the event tracking service: added logging and access control to system events.

Version 2023.08.3 08.08.2023

New features:

  • Added the option to mount devices with a height multiple of 0.5 U into rack.
  • Added the option to manage PDU dummy handlers in the platform interface. Read more in the documentation: https://docs.ispsystem.com/x/VQBIBw

Improvements:

  • Filters for the Model and Delivery columns have been added to the tables of the Inventory Management module.
  • Added support for HP (BL460c Gen9, DL360 Gen9, DL380 Gen9) and OpenYard (RS101 and RS201) servers.
  • Added the option to install Debian 12 on the server.
  • Added the option to sort IP address pools, VLANs.

Bug fixes:

  • Fixed the error that caused the status of IP address protection against accidental deletion to be displayed incorrectly.
  • Fixed the error that caused the size of OS template backups to displayed incorrectly.
  • Fixed the problem that caused a second boot partition to be added to a disk sized 3 TB or larger when installing Ubuntu OS.

Version 2023.08.1 01.08.2023

New features:

  • Added the possibility to configure integration with DNSmanager 6.

Version 2023.07.2 25.07.2023

New features:

  • Added the DC Map module. The module allows you to build a map of the data center, monitor the status and temperature of the equipment. Read more in the documentation: https://docs.ispsystem.com/x/GY0mCw

Version 2023.07.1 11.07.2023

New features:

  • Added the option to select a platform for blade servers found through the Server Auto-add module.
  • Added a simulated 3D view and the option to switch between racks into the Rack Visualization module.
  • Added the option to ignore server errors when provisioning the server.
  • Added support for Redfish handler for Lenovo ThinkSystem SR630 servers.

Improvements:

  • Changed the interface of tables: improved display of filters, pagination and group operations moved to the top part, checkboxes moved to the left column.
  • Changes on the Privacy tab in the client area: links to ISPsystem license agreements were removed; if the Links to Documents section is not filled out in client service settings, the tab will not be displayed. Link to ISPsystem User Agreement was moved to Platform Settings.
  • Added the display of additional fields to the table of server components in the warehouse.

Bug fixes:

  • Fixed the problem where deleting an ISO image did not free up disk space.
  • Fixed interface page freezing, which occurred when a server was given a MAC address belonging to another server in the platform.
  • Fixed the error that made it impossible to link a CPU in the server to a part in the warehouse.
  • Fixed the error that made it impossible to specify the "/" symbol in the RAM model creation and editing form.
  • Fixed the error that prevented validation of CPU socket creation during migration.

Version 2023.06.1 14.06.2023

New features:

  • Added display of MAC addresses on switch ports.
  • Added the option to migrate warehouse history from DCImanager 5. Read more in the documentation: https://docs.ispsystem.com/x/g52bCg

Improvements:

  • Improved getting up-to-date information about downloaded OS templates and ISO images when setting up a location.
  • Added the use of NetFlow statistics in the billing platform, if the platform uses the NetFlow statistics data by default.
  • Added the option to set session time for authorization in the platform. Read more in the documentation: https://docs.ispsystem.com/x/-LToAQ
  • Changed the display of the names of the "Barcode" and "Serial number" fields on the form for adding equipment to the delivery.
  • The maximum number of devices when adding equipment to the delivery has been increased to 100 units.
  • Sorting by whether a chassis is available has been added to the rack table.
  • Added support for managing Delta Tioga Pass servers using the Redfish protocol.
  • The component table for parts and other equipment with the status "In server" now displays the name of the server.

Bug fixes:

  • Fixed the error that caused the "Available on locations" column in the "Physical networks" table to not display data.
  • Inventory Management module. Fixed filtering by serial number in equipment tables.
  • Fixed the problem that caused connections between switches to be imported incorrectly when migrating from DCImanager 5.
  • Fixed the problem where server operation errors were not displayed in the interface.
  • Fixed the problem that caused chassis position in a rack to be calculated incorrectly when migrating from DCImanager 5.

Version 2023.05.2 16.05.2023

New features:

  • Added the option to upload ISO images from local device to the platform.
  • Added the option to specify the time zone to display the time in the platform. Read more in the documentation: https://docs.ispsystem.com/x/opKbCg
  • Added the option to remove equipment and components from the warehouse.

Improvements:

  • Added the option to filter the list of servers by "Blocked" status.
  • Added support for managing HP Gen9 servers via Redfish protocol.
  • Added the button that allows you to close all pop-up notifications.
  • Equipment Inventory Management module. Added the option to change the accounting currency.

Bug fixes:

  • Fixed the error that caused Clickhouse software not to start after an abnormal server reboot.
  • Fixed the problem that caused some queries in the global search to cause errors.
  • Fixed the error that caused multiple messages to be displayed when an update was available.
  • Fixed the problem with the Arista switch handler (eAPI) that could occur when processing large amounts of data.
  • Fixed the error that could cause notes in the server table not to be displayed.
  • Fixed the error, which caused incorrect displaying of NetFlow statistics in Grafana.
  • Fixed incorrect display of the rack when resizing the page.
  • Fixed display icons for pools for provisioning and release of servers available on all locations.

Version 2023.05.1 02.05.2023

Improvements:

Version 2023.04.2 18.04.2023

New features:

  • Added the option to automatically link free parts from the warehouse and components found after server diagnostics.
  • Added the option to create additional fields for components in the warehouse.
  • Added the option to block a user in the platform.

Improvements:

  • Added the option to display NetFlow statistics in the platform interface.

Bug fixes:

  • Fixed the problem that prevented Loki service from deleting logs older than 7 days.
  • Fixed the problem that caused disk partitioning to be performed incorrectly when installing OS with the kickstart template.

Version 2023.04.1 03.04.2023

New features:

  • Added the option to flexibly configure user permissions. If the platform has PowerDNS or IPmanager 6 integration modules installed, upgrade them before configuring. Read more in the documentation: https://docs.ispsystem.com/x/noKbCg
  • The Grafana start page now displays the platform dashboards.
  • Added progress display when installing the platform.
  • Added the option to apply patches to docker containers in a location. Read more in the documentation: https://docs.ispsystem.com/x/AISbCg
  • Added the option to enable the BMC console for iDRAC versions 6 and 9.

Improvements:

  • Disabling aggregation on Cisco Nexus switches now disables all ports in that aggregation.

Bug fixes:

  • Fixed the problem that could result in an unexpected error message on the equipment adding form.
  • Fixed the problem that could cause the OS template not to load on a location.
  • Fixed the error that could duplicate entries in the DHCP configuration file when starting operations on servers.
  • Fixed the problem that caused backup files larger than 100 MB to be deleted.
  • Fixed the problem that occurred when commissioning a server with custom parameters, which was found using the Server auto-add module.
  • Fixed the error that could cause tasks to freeze when updating the platform.
  • Fixed the error where DHCP interface configuration was incorrectly applied when configuring a location.
  • Fixed the error that caused the switch port and PDU lists to not display a note.
  • Fixed the error that could cause blade servers not to display the chassis on the edit form.
  • Fixed the problem that made it impossible to interact with OS templates without tags.

Version 2023.02.1 21.02.2023

New features:

Improvements:

  • The text of the backup error message now more accurately describes the problem.
  • Filtering and sorting functions are now available for fields added by the user.
  • Added the option to generate a name for parts retrieved from the server to move to the warehouse.

Bug fixes:

  • Fixed the error that appeared when trying to update an expired license to a valid one.
  • Fixed the problem with services freezing that occurred when restarting the platform.
  • Fixed the problem that caused items in the Switch Connection Settings tab to overlap.
  • Fixed the problem where copied OS templates were blocked after setting up a location.

Version 2023.01.1 25.01.2023

New features:

  • Added the option to search globally by user-created fields.
  • Added a recovery template for FreeBSD.

Improvements:

  • The server status now changes if the BMC sensor values go out of range.
  • Improved readability of the interface by changing the color scheme and increasing the contrast of text and graphic elements.
  • You can now add the chassis to the rack on the Add Blade Server form.

Bug fixes:

  • Fixed the problem that could cause the PDU statistics page not to open.
  • Fixed the problem that made it impossible to re-authorize in the platform after switching from the billing system.
  • Fixed the problem that caused the history of actions with the server to be displayed incompletely.

Version 2022.12.1 15.12.2022

New features:

  • Added the option to use two-factor authentication. Read more in the documentation: https://docs.ispsystem.com/x/N4C2CQ
  • The server errors now include information about BMC sensors whose values are out of range. To display the information, enable notifications from BMC sensors.
  • Added the option to create additional fields to the equipment using the API. Read more in the documentation: https://docs.ispsystem.com/x/CYCrCQ
  • Added the option to send a test email to check the connection when setting up a mail server.

Bug fixes:

  • Now racks with special characters in their names are migrated correctly from DCImanager 5.
  • Fixed the error that made it impossible to edit an IP address if there was no comment attached to the address.
  • Fixed the unauthorized error when viewing statistics. The error occurred if the administrator logged into the platform under the user account for which ACL was configured.
  • Fixed the error that could occur when saving the switch configuration to ROM.

Version 2022.11.1 24.11.2022

New features:

  • Added the option to reset a previously created IPMI proxy session or a connection to it.
  • Added information about the version and date of the last change of the OS template or operation.
  • Added the option to automatically update OS templates and operations.
  • Added the option to automatically save configuration changes to switches using Common (SNMP) and Cisco Catalyst (SNMP) handlers to non-volatile memory.
  • The option to change user passwords has been added for platform administrators.

Improvements:

  • Improved the operation of the statistics collection services. Clickhouse is now used to store statistical data.
  • BMC periodic polling has been improved. Now most of the operations are performed on the location server and do not create load on the platform server.
  • Improved PDU ports table management: added sorting, filtering, ability to resize and change columns visibility.

Bug fixes:

  • Fixed the problem that prevented a found server with a non-unique BMC IP address from being added.
  • Fixed the problem that caused the warehouse header in the Equipment Inventory Management module to be displayed on top of the main menu in Safari.

Version 2022.10.2 26.10.2022

New features:

Improvements:

  • Improved aggregate port polling mechanism via eAPI for Arista switches.
  • Added Docker version check when installing and upgrading the platform. If the Docker version is lower than the minimum allowed, the action will end in an error.

Bug fixes:

  • Fixed the error that made the button to open the BMC console appear with a delay.
  • Fixed the error that caused the location to be set up only on the second attempt.
  • Fixed the error that caused BMC proxy module not to be installed under some accounts with the Administrator role.
  • The report generation button has been removed from the interface of accounts with the User role.

Version 2022.10.1-3 15.11.2022

New features:

  • Added the option to create a custom VPU handler.
  • Added the option to manually edit the server configuration generated based on the results of diagnostics.
  • Added the option to quickly move from location dashboard to equipment with status errors.
  • Added the option to install operating systems in groups.
  • Added the option to specify BMC connection parameters when putting a server into operation.
  • Added the option to delete the only IP address on the server.
  • Added the option to export server reports according to configured templates: about main systems, about firmware, about components. Read more in the documentation: https://docs.ispsystem.com/x/TwBIBw
  • Added the option to connect server to multiple PDU ports. Read more in the documentation: https://docs.ispsystem.com/x/q57oAQ.
  • New operating system templates added: Ubuntu 22.04, AlmaLinux 9, Windows 2022.
  • Added the option to put the UPS from the warehouse into operation.
  • Blade servers in the chassis can now be moved between racks.
  • Added the option to filter global search results.
  • Added the global search history.
  • Added the option to run diagnostics and recovery operations, for situations when there are no connections to PDU and BMC (Intel AMT) on the server.

Improvements:

  • The schedule for local platform backups is now created by default.
  • Now, if the switch port information is not received, the switch table displays "No information".
  • Added the possibility to generate reports in the server card and rack card. Added notifications on reports: generation, readiness, whether unread reports exist. Read more in the documentation: https://docs.ispsystem.com/x/TwBIBw.
  • You can now add your own documents in the Client Service section, which are available for clients to view in their client area.
  • Now messages about rack changes and server moves to warehouse and operation are recorded in the history of the server.
  • In the Rack Visualization module, the display of the service unit's parameters is now not shifted over the edge of the screen.
  • Now when you go to the list of blade servers from the chassis, a list filtered by the servers in that chassis opens.
  • All tags used in operating system templates have been added to the list of script tags.
  • The stability of the "Proxying BMC through a location server" module has been improved.
  • The "Host name" field is now optional when installing the operating system. If the parameter is not specified, the domain name localhost will be used for the Unix OS family, while for the Windows OS the domain name will be generated automatically.
  • Added the option to display comments on the server in the server list.

Bug fixes:

  • Fixed the problem that sometimes prevented diagnostics from running on the server.
  • Fixed the error that appeared when opening an empty IP address pool.
  • Fixed the "Something went wrong" error that appeared when connecting to BMC server via proxy.
  • Fixed the problem that sometimes made it impossible to edit blade server settings.
  • Fixed the problem that made it impossible to delete a server IP in some cases.

Version 2022.10.1 11.10.2022

New features:

  • Added the option to specify a filter by configuration specified by the user in the server table.
  • Added IP address uniqueness check in the BMC server connection settings. Now a warning message appears when specifying a BMC IP address that is already in use.

Improvements:

  • The form for adding equipment to the warehouse now displays the parameters of the selected equipment model.
  • When selecting "Auto", "1 Gbit/s", "10 Gbit/s" speeds, the "Full-duplex" operation mode is set automatically in the switch port card.
  • The physical network adding form now displays a hint about the input format.
  • Now the lock icon does not appear in the switch connections.

Bug fixes:

  • Fixed the issue that sometimes caused switch statistics not to be collected due to duplicate ports.
  • Fixed the issue that sometimes caused the "Fail to register task" error.

Version 2022.09.2 27.09.2022

New features:

  • Added the option to manually edit the server configuration generated based on the results of diagnostics.
  • Added the option to quickly move from location dashboard to equipment with status errors.
  • Added the option to install operating systems in groups.
  • Added the option to specify BMC connection parameters when putting a server into operation.
  • Added the option to delete the only IP address on the server.

Improvements:

  • The stability of the "Proxying BMC through a location server" module has been improved.

Bug fixes:

  • Fixed the "Something went wrong" error that appeared when connecting to BMC server via proxy.
  • Fixed the error that prevented connecting to BMC servers via proxy after platform update.

Version 2022.09.1 13.09.2022

New features:

  • Added the option to filter global search results.
  • Added the global search history.
  • Added the option to run diagnostics and recovery operations, for situations when there are no connections to PDU and BMC (Intel AMT) on the server.

Improvements:

  • The "Host name" field is now optional when installing the operating system. If the parameter is not specified, the domain name localhost will be used for the Unix OS family, while for the Windows OS the domain name will be generated automatically.
  • Added the option to display comments on the server in the server list.
  • The schedule for local platform backups is now created by default.

Bug fixes:

  • Fixed the problem that occurred when rebooting a server connected only to a PDU.
  • Fixed the problem that made it impossible to delete a server IP in some cases.

Version 2022.08.3 30.08.2022

New features:

  • New operating system templates added: Ubuntu 22.04, AlmaLinux 9, Windows 2022.
  • Added the option to put the UPS from the warehouse into operation.
  • Blade servers in the chassis can now be moved between racks.

Improvements:

  • You can now add your own documents in the Client Service section, which are available for clients to view in their client area.
  • Now messages about rack changes and server moves to warehouse and operation are recorded in the history of the server.
  • In the Rack Visualization module, the display of the service unit's parameters is now not shifted over the edge of the screen.
  • Now when you go to the list of blade servers from the chassis, a list filtered by the servers in that chassis opens.
  • All tags used in operating system templates have been added to the list of script tags.

Bug fixes:

  • Fixed the error that appeared when opening an empty IP address pool.

Version 2022.08.2 16.08.2022

New features:

Improvements:

  • Now, if the switch port information is not received, the switch table displays "No information".
  • Added the possibility to generate reports in the server card and rack card. Added notifications on reports: generation, readiness, whether unread reports exist. Read more in the documentation: https://docs.ispsystem.com/x/TwBIBw.

Bug fixes:

  • Changed responses to API requests for server list (GET server) and server details (GET server/{server_id}). The pdu_connection field is now an array of JSON objects of connections to the PDU.
  • Fixed the problem that sometimes made it impossible to edit blade server settings.
  • Fixed the error that appeared when opening the list of BMC users.

Version 2022.08.1 04.08.2022

New features:

  • Added the option to export server reports according to configured templates: about main systems, about firmware, about components. Read more in the documentation: https://docs.ispsystem.com/x/TwBIBw
  • Added the option to create a custom VPU handler.

Bug fixes:

  • Fixed the problem that caused the server to disappear from the table when opened in the user interface.
  • Fixed the problem that caused the server card to not show some connections to the switch.
  • Fixed the problem that caused supply and supplier add forms to be displayed in a cycle.
  • Fixed the problem that caused the form for configuring servers auto-addition via PXE not to open.
  • Fixed the problem that caused an error on the modules page.
  • Fixed the problem that was causing an error in the user interface when trying to add a VLAN.
  • Fixed the problem that caused some servers in the table to be displayed with an incorrect "Deleted" status.
  • Fixed the problem that sometimes prevented diagnostics from running on the server.

Version 2022.07.2 19.07.2022

New features:

  • Added the ability to attach delivery note files to the delivery in the Equipment Inventory Management module.

Improvements:

  • Improved global search: now search results are displayed more clearly, removed grouping by location/warehouse, added columns with found object ID and location/warehouse name.
  • Added automatic server reboot on cancellation of recovery operation.
  • Added the ability to filter Redfish logs by ID, status and event fragment.
  • Added the ability to collect statistics from the Aten PDU.

Bug fixes:

  • Fixed the problem that caused the template loading and deleting statuses to be updated only after reloading the page.
  • Fixed the problem that caused an error when editing an empty user group.
  • Fixed the problem that caused the list of VLAN members to show ports on switches that are in a location other than the current or selected location.

Version 2022.07.1 05.07.2022

New features:

  • Added the ability to globally search for equipment and other platform objects by name and properties. Read more in the documentation: https://docs.ispsystem.com/x/frroAQ.
  • Added the ability to group commissioning of servers found through the Server Auto-adding module.

Improvements:

  • Added the ability to sort and paginate BMC Redfish logs.
  • In the list of servers, the ability to filter servers without a rack has been added.

Bug fixes:

  • Fixed the problem that prevented saving new parameters when editing switches with Cisco Nexus handler (NX-API).
  • Fixed the problem that could cause server connections to switch ports to be duplicated.
  • Fixed the problem of incorrect equipment count in the rack in some situations.

Version 2022.06.2 21.06.2022

Breaking changes:

  • Changed API for working with the Inventory management module. When creating parts in the warehouse, it is now necessary to pass the delivery ID instead of the number and date of delivery. When creating a location with the Inventory management module enabled, it is now necessary to pass the ID of the warehouse to which the location is linked.

New features:

Improvements:

  • Added the ability to specify a price for equipment in the warehouse.

Bug fixes:

  • Fixed the problem that occurred when creating BMC users.
  • Fixed an issue that caused the form for moving components to the warehouse to close when creating a new model of equipment.
  • Fixed the problem that caused NICs to appear in the list of server accessories in the list of fans.
  • Fixed the problem where editing a blade server would redirect to the list of servers.
  • Fixed the problem that could cause BMC proxying for a user not to work.
  • Fixed the problem where setting up a location and loading templates would freeze when restarting the platform.

Version 2022.06.1 07.06.2022

New features:

  • Added the ability to view BMC Redfish logs in tabular form.
  • Added the ability to create users with umlauts in email address.
  • Added a common IP address table. All addresses assigned to a location can now be managed from the same table.
  • Added the ability to create platform backups via NFS and SMB (for details see https://docs.ispsystem.com/x/FID_BQ).
  • Added support for Aten PDUs.

Improvements:

  • Improved the mechanism for determining the model, vendor and serial number of drives during diagnostics.
  • Added the ability to sort and filter IP addresses in "Physical networks" and "IP address pools" sections.

Bug fixes:

  • Fixed the error that allowed to delete a server search template when search was running.

Version 2022.05.2 24.05.2022

Bug fixes:

  • Fixed the problem where BMC console and web interface proxying did not work after platform restart.
  • Fixed the problem that caused BMC proxying not to work if the server did not have the ISO images specified in the platform.
  • Now a validation error appears on the form for creating an IP address pool when entering the name of an existing pool.
  • Fixed an error in the list of server components that appeared when adding equipment of the Other type from the Equipment Inventory module.

Version 2022.05.1-1 16.05.2022

Bug fixes:

  • Fixed the problem which could prevent PTR records from being created in PowerDNS.

Version 2022.05.1 12.05.2022

New features:

Bug fixes:

  • Fixed the problem that caused the diagnostic time to be displayed incorrectly.
  • Fixed the problem where macro values were not passed to the scripts when installing the OS.
  • Timeout for checking connection to location via SSH has been increased from 20 to 40 seconds.
  • Fixed the problem where an uncompressed file was downloaded instead of an archive when getting a backup from the interface.

Version 2022.04.2 26.04.2022

Bug fixes:

  • Fixed the problem that caused BMC proxying not to work if ACL is enabled.
  • Fixed the problem that caused the platform backup restore from a backup not to work.
  • Fixed the error that occurred when displaying a large number of users in the list.
  • Fixed the error that sometimes made it impossible to delete a user.

Version 2022.04.1 12.04.2022

Bug fixes:

  • Fixed a false error display that occurred during S.M.A.R.T. diagnostics when checking Reserved Block Count.
  • Fixed the error that prevented opening the IP address pool card.
  • Fixed incorrect display of equipment from the "Other" category in the list of server components.

Version 2022.03.3 29.03.2022

New features:

  • Added the ability to install the platform and add locations running under AlmaLinux 8.
  • Added the ability to move the blade server to another chassis.
  • Branding information is now added to emails.

Improvements:

  • Autofilling of platform and chassis data has been added on the server creation form when creating a server.

Bug fixes:

  • Fixed platform freeze that occurred when redirecting to the login page.
  • Fixed a validation error message that occurred when adding equipment if the Equipment Inventory module is installed in the platform.
  • Fixed the problem due to which it was possible to download the BMC console after installing the BMC Proxying module only after reloading the page.
  • Fixed the error that prevented adding a platform for a blade server on the server adding page if no platform for a rack server was created.
  • Now, if the Equipment Inventory module is installed in the platform, the Discard link appears instead of the Delete link during group operations on servers.
  • Fixed the error that appeared when creating BMC users.

Version 2022.03.2 15.03.2022

Improvements:

  • Now the main menu is not displayed when the first location is created.
  • Added the possibility to disable the mail server.
  • Added the possibility to connect a mail server without authorization.
  • Added display of the identifier in the list of OS templates.
  • Added automatic filling of host name when starting OS installation.
  • Added the possibility to select all VLANs in trunk ports list simultaneously.
  • Loading of tables with large amounts of data has been accelerated.

Bug fixes:

  • Fixed the error where periodic polling of switches sometimes did not update data.
  • Changed the display of the error message that appeared when checking the uniqueness of the device name.
  • Fixed the error that prevented saving parameters of a switch port connected to the server.
  • Fixed the display of total and occupied IPv6 addresses.
  • Fixed the error that caused focus to disappear from the input field in the modal window when creating a platform.
  • Fixed display of time in diagnostics report in Safari browser.
  • Fixed the error that made it impossible to select certaub free units in the rack.
  • Fixed the error that allowed specifying the server size when creating a server.

Version 2022.03.1 01.03.2022

New features:

  • Added FreeBSD OS templates.
  • Added support for BMC consoles for Dell iDRAC6 servers.

Improvements:

  • The button for adding setting in the "Server Auto-add" module is now blocked if there are no available physical networks.

Bug fixes:

  • Fixed the display of trunk port status when configuring switch ports.
  • Fixed the error that made it impossible to save a server without specifying a MAC address.
  • Fixed the error that made it impossible to edit IP addresses in the list of physical networks.
  • Fixed the problem where server component status notifications could cause high CPU load.

Version 2022.02.1 14.02.2022

New features:

  • In the "Equipment inventory" module, the ability to account for UPS has been added.

Improvements:

  • Now when you select a VLAN for a switch port, the name and number of the network are displayed in the list.
  • Improved display of a large number of locations on the main page of the platform.
  • Added a check for free space on the location server when loading operating system templates.
  • Added the ability to edit platform size if DCImanager has no servers with such a platform.

Bug fixes:

  • Fixed the problem that caused DCImanager software to take up a large amount of disk space.
  • Fixed the problem that caused the bottom block of some tables to be displayed in the wrong place.
  • Changed the display of backups that are not available for downloading.
  • Fixed the error that caused the list of server components to display only a part of the equipment.
  • Fixed the error that appeared when filtering servers by status under a user account.
  • Fixed the error that occurred when viewing server diagnostics errors.
  • Fixed an error in mounting ISO images, which appeared due to diagnostic errors.

Version 2022.01.2-1 03.02.2022

Bug fixes:

  • Fixed the error that prevented server operations from being performed under the user account.

Version 2022.01.2 25.01.2022

New features:

  • Added the ability to export data from tables in CSV format in the Equipment Inventory module.
  • Added support of BMC consoles for HP Gen8 servers.

Improvements:

  • Notification settings are now checked for uniqueness during creation and editing.
  • The Cisco Catalyst switch handler has been improved: now the port list displays the ports of the switches in the stack.

Bug fixes:

  • Fixed incorrect filtering by rack in the server table.
  • Fixed incorrect display of blade servers in the Rack Visualization module.
  • Fixed incorrect display of free-standing devices in the UPS table.
  • Fixed the error that caused racks from other locations to appear in the rack table if more than 10 locations were created.
  • Fixed the error that caused the OS template table to display templates from other locations if more than 10 locations were created.
  • Fixed the display of long serial numbers in the "All equipment" table of the Equipment Inventory module.
  • Fixed the problem that caused high CPU load on the server with the platform.
  • Fixed the problem where the FRU BMC information was getting data from other server devices.
  • Fixed the error that occurred when selecting the first location if a large number of locations were created.
  • Fixed the incorrect display of the OS templates loading window.

Version 2022.01.1 11.01.2022

New features:

  • Disk information has been added to the list of components obtained via the Redfish protocol (available only for DCImanager 6 Infrastructure edition).
  • For servers that connect to BMC using the Redfish protocol, it is now possible to set up notifications on hardware status changes (only available for DCImanager 6 Infrastructure edition).
  • For servers that connect to BMC using the Redfish protocol, the ability to mount ISO images has been added (available only for DCImanager 6 Infrastructure edition).
  • Added the display of BMC and server BIOS versions in the "Information" tab of the BMC section (available only for DCImanager 6 Infrastructure edition).

Improvements:

  • A filter by power status has been added to the list of servers.

Bug fixes:

  • The maximum length of the platform name has been increased from 49 to 255 characters.
  • Fixed the error that prevented backing up to an external storage with an SSH key connection.
  • Fixed the error that caused the table filter form to be duplicated.

Version 2021.12.1-1 23.12.2021

Improvements:

  • Fixed the problem with the filtering server list by chassis, platforms and racks.

Version 2021.12.1 15.12.2021

New features:

  • Added the statistics section to the switch card.
  • Added the ability to obtain server components via BMC using the Redfish protocol.

Improvements:

  • Support for Cisco Catalyst C2960L and C3850 switches has been added.
  • In the UPS table, filtering has been added by the "Charge", "Load", "Output Power" and "Power Consumption" columns.
  • Filtering by presence of errors in the "Server status" column has been added to the list of servers.
  • Increased the height of tables, changed the display of forms and device cards.
  • In the Equipment inventory module, the ability to display table rows in a compact form was added.
  • Filtering by the "Switch" column has been added to the table of switches.
  • Filtering by the "PDU" column has been added to the PDU table.

Bug fixes:

  • Fixed the problem in the IPmanager integration module with, due to which the module was unable to save connection settings.

Version 2021.11.2 30.11.2021

New features:

  • Added the possibility of integration with AD/LDAP domain authorizations.
  • The date of the latest update and the date of the current version have been added to the information about the platform.
  • Added the ability to back up the platform through the user interface.
  • Added the ability to load custom PDU handlers. https://docs.ispsystem.com/x/MgBaB

Improvements:

  • The Dell switch handler has been adapted to work with PowerConnext 5548.
  • Changed the order of the Racks and Servers items in the main menu.
  • The list of supported operating systems for locations has been clarified on location adding form.

Bug fixes:

  • Fixed the problem with Arista switch polling when the VLAN list contained invalid values.
  • Fixed resetting the "No owner" filter in the servers table when a filter by user was selected along with it.
  • Fixed spontaneous transition from server card to server table.
  • Changed the position of the Network and Power columns in the server table.
  • For BMC sensors the display has been corrected and the stability of information feed has been improved.

Version 2021.11.1 16.11.2021

New features:

  • Added the ability to collapse and unfold long lists of BMC sensors.
  • Added the ability to filter servers that have no owner.
  • In the "Equipment inventory" module, the display of the number of devices for each type of equipment in the Other section, as well as the ability to quickly filter them has been added.

Bug fixes:

  • Fixed the problem due to which servers could remain in the old rack when moving chassis between racks.
  • Fixed the problem that caused the server not to delete connections when moving it to a warehouse.
  • Fixed the problem that prevented editing a server if the limit on the number of equipment per license was reached.
  • Fixed the problem that could cause scripts not to work on some operating systems.
  • In the user interface, the "In use" tab has been deleted.
  • Fixed the problem where the address in the list of IP addresses of physical networks could not be edited.
  • Fixed display of IP address tables in pool, platform, and blade server cards.
  • Fixed the problem that prevented creating an APC UPS.

Version 2021.10.2 26.10.2021

New features:

  • Global interface update. The main menu has been replaced by an interactive sidebar, tables no longer have a fixed width, and a new view of forms and entity pages has been implemented.
  • It is now possible to manage access control lists (ACLs) from the platform interface.
  • Now the location is automatically configured after it is created.
  • Progress of loading ISO images to the location has been added.
  • Added displaying the size of ISO images at a location. The size is displayed only for newly uploaded images.

Improvements:

  • Integration of billing systems under any administrator account can now be configured.
  • Fixed the issue with Loki freezing while updating.

Bug fixes:

  • Fixed the issue that caused the browser's web interface for BMC HP iLO4 to not open when proxying BMC.
  • Fixed sorting by IP addresses in "Servers", "IP pools" and "Physical networks" tables.

Version 2021.10.1 05.10.2021

New features:

  • Added the ability to edit notifications
  • On the rack visualization page, the ability to install equipment when selecting a particular unit has been added

Improvements:

  • New filtering options in tables have been added. It is now possible to filter columns by exact or partial match of rows, as well as by number range
  • Added automatic creation of PTR zones when creating networks in the platform. Please update the "PowerDNS Integration" module to the latest version

Bug fixes:

  • Fixed the error that could lead to license being blocked if the license update failed.
  • Fixed the problem with freezing of location settings.
  • Fixed the "Duplicate entry" error that occured when proxying requests to IPmanager 6 in the "Integration with IPmanager 6" module
  • Fixed the error that occurred when granting access for the technical support team
  • Fixed the appearance of tooltips when there are no available units in the rack to install equipment
  • Fixed the error that caused the update to display a list of changes to the previous platform version

Version 2021.09.2 22.09.2021

New features:

  • The "Chassis" section has been added to the server list.

Improvements:

  • Added waiting for switch port state change into the Common (SNMP) handler.
  • Added action menu in server and chassis cards in the rack visualization section.
  • It is now possible to add the "Free" column to the rack table in full mode.
  • In the full report, the server components that could not be identified will be listed as "not defined".
  • Rack card. The "no data" error has been removed in temperature mode if no data collection is configured on the server.
  • Added default remap rules for TFTP.
  • In the rack visualization section of the open server card, processing of movement to the warehouse has been added.
  • Added zero state of IP addresses in the server card.
  • Added display of the number of free IP addresses in the full mode of the pool table.

Bug fixes:

  • Fixed the issue with operation of regular-version switches.
  • Fixed the problem with navigating to the platform as a user from the billing system.
  • Fixed the error that caused new DCImanager templates not to be displayed in the billing system.
  • Fixed the error that occurred after a platform update causing tech support contacts to change to the default ones.
  • Fixed the error that could cause the DHCP server to reboot.
  • Opening animation has been removed from the rack card if another unit's contents are already open.
  • Fixed the error causing the state of the item "Networks and Pools" not to change when switching locations on the dashboard.
  • Fixed the limitation on the maximum length of a domain name
  • Fixed duplicate OS template loading status.
  • On the OS installation page, the hint for the OS template with an error has been corrected.

Version 2021.09.1-2 10.09.2021

Bug fixes:

  • Fixed the error, which caused freezing of the location setup operation.

Version 2021.09.1 07.09.2021

Improvements:

  • Added waiting for switch port state change into the Common (SNMP) handler.
  • On the OS installation page, sorting of the OS from newer versions to older versions has been added.
  • On the server addition form, the tooltip displayed when there is no physical network has been changed.

Bug fixes:

  • Fixed the error that caused the list of racks, networks and switches to open when switching locations.
  • Fixed the problem in the operation of regular-version switches
  • UPS editing has been blocked while an operation is in progress.

Version 2021.08.2-1 24.08.2021

Bug fixes:

  • Fixed the platform update error.

Version 2021.08.2 24.08.2021

New features:

  • The possibility to go to the blade server card from the chassis has been added in the "Rack visualization" module.
  • In the VLAN members table, added the possibility of filtering and sorting.

Improvements:

  • Added the support of Cisco Small Business switches.
  • The link to the section where VPU networks for IPMI can be created has been added to the form for server connection to IPMI. The link is displayed if the "VPU" module is enabled and VPU networks for IPMI have not been created.
  • Deleting service IP addresses, which are not broadband or network addresses is now permitted.
  • Information about the "Low disk speed" error has been added to the server diagnostic results.
  • Fixation of the right column to the top window margin was added in the "Rack visualization" module, if the rack components do not fit the screen.

Bug fixes:

  • Fixed freezing, which occurred when deleting an OS template, if numerous operations had been performed with the template.
  • Fixed the display of the process of template loading to a location.

Version 2021.08.1 10.08.2021

New features:

  • Added the display of the number of servers in the chassis with different temperature levels to the rack map.
  • Added the ability to load IPMI console for new ASRockRack server models.
  • Added the ability to create a location on a server with Ubuntu 20.04.

Bug fixes:

  • Fixed the error that occurred when configuring a location if an incompatible version of docker-compose was installed on the location server.
  • Fixed the error that occurred when logging into the platform under a user account.
  • Fixed the error in polling Nexus switches that occurred if the list of MAC addresses could not be obtained.

Version 2021.07.2 27.07.2021

New features:

  • Added AlmaLinux installation template.
  • In the Rack Visualization module, the display of the list of blade servers has been added when selecting a chassis.
  • In the Rack Visualization module, the ability to create server connections to IPMI, Intel AMT, PDUs and switches has been added.

Improvements:

  • Added support for D-Link 3200B and D-Link 3200C switches.
  • Added support for Brocade switches.
  • In the Rack Visualization module, automatic updating of equipment information has been added.
  • In the Rack visualization module, selection of the selected unit has been added.

Bug fixes:

  • Fixed display of acceptable value range in notifications.
  • Fixed the error that caused the rack list to not save the selected display mode (full or compact).
  • Fixed the error that made it impossible to add an ISO image to a location.

Version 2021.07.1 13.07.2021

New features:

Improvements:

  • Added the option to enable compact view in the server table.
  • Added support for Zyxel GS2200 and Zyxel XGS switches.

Bug fixes:

  • Fixed the error that made it impossible to delete an IPMI user on HP and Dell servers.
  • Fixed the problem that made it impossible to get IPMI information on some Cisco servers.
  • Fixed the display of FRU INFO in the "IPMI" section of server info when the server is down.

Version 2021.06.4 29.06.2021

New features:

  • Added support for Huawei switches.
  • The "Rack visualization" module has been added. The module shows the map of the rack in a graphical form with the ability to display the temperature of devices.
  • The "Statistics" section has been added to the UPS card. The section displays graphs of battery charge, load, power consumption and output power.
  • The "Statistics" section with the power consumption graph has been added to the PDU card.
  • Added proxying support for ASRockRack IPMI.

Improvements:

  • Automatic change of state of the network and IP address pool settings group when creating the first location has been added to the dashboard.
  • On the installation page of the operating system, the display of SSH keys from the client area, the ability to remove and modify downloaded SSH keys was added.
  • Filtering, sorting, and compact view options have been added to the user table.
  • Added the option to enable compact view in the rack table.
  • In the table of pools the ability to filter pools by name, enable a compact view, and change the width of the columns was added.
  • Added the ability in the platform interface to install VMware ESXi on the server

Bug fixes:

  • Fixed the message about lack of free units in the rack for the selected platform on the server creation and editing pages.

Version 2021.06.3 16.06.2021

Bug fixes:

  • Fixed an error in obtaining the role for the second and subsequent administrators.

Version 2021.06.2 15.06.2021

New features:

  • Added the ability to work with a UPS.

Improvements:

  • Added the handler for RPCM PDU.

Bug fixes:

  • Fixed the error that occurred when adding a blade server to a chassis slot other than the first one.
  • Fixed the error that occurred when creating the script.
  • Fixed the error in updating the IPMI user list.
  • Fixed the error that occurred when adding a blade server with a platform of more than one slot size.

Version 2021.06.1 01.06.2021

New features:

  • In the lists of recipes, server IP addresses, ISO images, physical networks, the ability to select columns to display and change the size of the columns was added.
  • Checking for IPMI console support has been added. If DCImanager does not currently support the IPMI console of a given vendor, the "Open console" link is disabled.
  • Added the ability to configure notifications for errors occurring during server diagnostics.
  • Added display of the switch polling status in the settings of server connection to switches.

Improvements:

  • Added a check for forbidden characters in the password when installing the OS template to the server. Each template can have its own set of forbidden characters.
  • Added the possibility to change access settings for scripts from ISPsystem repository.

Bug fixes:

  • Fixed the problem that could cause operations not to start if the network interfaces of a location were configured after it was added to the platform.
  • Fixed the error that caused the list of all equipment in the "Equipment inventorying" module not to be updated after adding the first device.
  • Fixed the error that did not allow to change server network settings.

Version 2021.05.1 18.05.2021

New features:

  • Added the ability to monitor servers by temperature, voltage and fan speed. If a server problem is detected, administrators will be notified via email and in the platform interface. Read more in the documentation: https://docs.ispsystem.com/x/wvC4Ag

Improvements:

  • In the "Connections" section of the server, information about the switch polling has been added.
  • Added display of the total amount of RAM in the "Components" section of the server.
  • Added the ability to open IPMI HTML5 console for Cisco servers.
  • Added the handler for D-Link switches.

Bug fixes:

  • Fixed constant refreshing of items in the report on server components, which did not allow to copy the text.

Version 7.4.0 04.05.2021

New features:

  • Added the ability to change the displayed columns and their size in most tables of the platform.

Bug fixes:

  • Fixed the error that occurred when entering the switch or PDU size manually.
  • Fixed the error that occurred when editing a drive type with an empty note or alias.
  • Fixed the problem that could occur when creating a new IPMI user from the interface on Dell servers.

Version 7.3.0 27.04.2021

Improvements:

  • The MAC address of the server is no longer required when creating a server. Please note that OS installation, diagnostics, recovery, and boot from ISO image will not be possible on servers without MAC address.

Bug fixes:

  • Fixed the problem that could cause IPMI proxying and interrupting operations to fail.
  • Fixed the error where editing "other" equipment would change its status to "At warehouse".
  • Fixed a rarely reproducible error that appeared when editing "other" equipment from the list of "All equipment".

Version 7.2.0 20.04.2021

Improvements:

  • Added the ability to change the handler if there are no ports at the power distributor or switch when entering equipment into operation from the warehouse.

Bug fixes:

  • Fixed the problem where the name of the installed OS was not deleted after performing a diagnostic with a disk erase on the server.
  • Fixed the problem with editing IPMI users due to an empty note.

Version 7.1.1 15.04.2021

Bug fixes:

  • In the "Equipment inventory" module, an error was fixed that prevented adding components and equipment from the "Other" section without specifying the dates of delivery, warranty expiration and reservation.

Version 7.1.0 13.04.2021

New features:

  • In the settings of the platform the section "Technical contacts" was added.
  • Added history for equipment from the "Other" section in the "Equipment inventory" module.

Bug fixes:

  • Fixed the error that occurred when trying to run a disk cleanup if the diagnostic template had updates.
  • Fixed the error that occurred when removing a part from the server.
  • In the module "Equipment inventory", the error that occurred during the editing of the equipment card has been corrected. The error occurred if the date of delivery, warranty expiration or reservation was specified for the equipment
  • In the module "Equipment inventory", generation of barcodes for equipment from the section "Other" was corrected.

Version 7.0.0 06.04.2021

New features:

  • In the Equipment inventory module, the Other section was added for inventorying of cables, patch panels, rack shelves, socket blocks and miscellaneous types of equipment.

Improvements:

  • Added confirmation request for "Integration with IPmanager 6" plugin installation.

Bug fixes:

  • Fixed the problem, because of which records in Russian were not shown in the history of the server .
  • Fixed the error that occurred when logging into a user account from the administrator's account.
  • Fixed the discrepancy between IP addresses in DCImanager and IP addresses allocated by IPmanager 6 that appeared when editing the network.
  • Fixed the error of creating a blade server if no platform or chassis is created in DCImanager when the creation form is opened.
  • Fixed the problem that caused the selected loader for a particular server to reset if the operation was started on templates without an alternate loader.
  • Fixed the problem with enabling the port that could occur on Juniper switches when trying to unlock a server if the switch port was already enabled.
  • Fixed the problem with getting VLAN information on some Cisco Nexus switches.
  • Fixed the problem with launching scripts in Ubuntu and Debian operating systems.

Version 6.15.0 23.03.2021

New features:

  • The ability to work with PDUs was added to the "Equipment inventory" module.
  • Added iPXE loader selection for Debian 10, 9 and Ubuntu 18.04, 20.04 templates.

Improvements:

  • Fixed the transition from server and switch cards to the equipment inventory table, if the card was opened from the "Equipment inventory" module.
  • In the equipment inventory tables, location display for devices in operation was added.
  • Added a check for the length of the "Type or model" field for switches in the "Equipment inventory" module.
  • In the "Equipment inventory" module for switches in use, the ability to specify the number of ports and device model has been added.

Bug fixes:

  • Fixed the rare error that prevented setting a new partition size in manual partitioning when installing OS on a server.
  • Fixed button locking and absence of indicator when adding a pattern for loading ISO images.
  • Fixed the error that prevented adding a blade server when selecting a platform greater than one unit in size.
  • Fixed reappearance of the new version release notification.
  • Fixed display of the name of the installed OS in the server status.
  • Fixed incorrect calculation of the device position in the rack when entering the size in units manually.
  • Fixed erroneous frequency reset on RAM type editing form.
  • Fixed display of information about blade server location in a rack in the server list

Version 6.14.0 09.03.2021

New features:

  • In the "Equipment inventorying" module, the ability to work with switches has been added.

Improvements:

  • The "Warehouse" module was renamed to "Equipment inventorying".
  • In the "Equipment inventorying" module, the display of a large number of equipment items in general filters has been improved.
  • In the "IPMI" section of the server card, added highlighting of rows in the sensor table when hovering on it.
  • The display of components added from the warehouse before the diagnostics was fixed in the server card.

Bug fixes:

  • Now the default server platforms are not restored after deleting and restarting DCImanager.
  • Fixed the error that prevented copying an OS template for which an update is available.
  • Fixed template display: now templates that were copied from another location are not displayed for the location.
  • Fixed the "Add connection" button in the "Connections" section of the server card, added a hint if the button is not active.
  • The "In server" status is blocked for parts in the "Equipment inventorying" module if there are no servers in operation.

Version 6.13.0 24.02.2021

New features:

  • Added descriptions for the events of server blocking and unblocking in its history.
  • Added a server card for the "Warehouse" module, which allows you to edit server parameters.

Improvements:

  • The settings in the server card are divided into "Main" and "Network" tabs

Bug fixes:

  • Fixed the problem where the IPMI URL was automatically changed to the default URL after manual editing.
  • Disabled the ability to link server components to parts in the warehouse if there are no matching parts in stock.
  • Fixed a problem with the APC PDU handler that caused the DCImanager PDU not to wait for its state to change when turning a port on or off.
  • Fixed the error that appeared when moving components from the server to the warehouse.
  • Corrected the substring of the "In reserve" status for equipment in the warehouse.
  • Fixed "Invalid time value" error in IPMI card, which occurred in Safari browser.

Version 6.12.0 15.02.2021

New features:

  • Added server boot mode selection in CentOS 7 diagnostic, repair and installation operations. For servers that have problems booting via PXE, an alternative iPXE boot loader can be selected.

Improvements:

  • Added the hint about possible loss of connection to IPMI or Intel AMT when changing server access settings.
  • Information on the board, product, platform and FRU device has been added to the item of IPMI parameters of the server.
  • Improved display of information from IPMI sensors - the data is divided into 3 groups: CPU, RAM and others.

Bug fixes:

  • Fixed the problem due to which incorrectly filled out form fields did not have a red outline.
  • Fixed the problem when closing the drop-down menu in the server card would cause the server card itself to close.
  • Fixed the problem that caused an error message to appear when opening IPMI user settings.

Version 6.11.0 09.02.2021

Improvements:

  • Added the display of the progress of unpacking the archive with the OS template to the location.
  • Added the ability to download IPMI console for Cisco servers UCSC-C220-M2 and UCSC-C220-M3

Bug fixes:

  • Fixed the problem that caused periodic polling to display an IPMI status of "Undefined".
  • Fixed the problem that caused the menu in the open server card to be empty
  • Fixed the validation of the "Note" field in the window of group editing of equipment in the Warehouse module .
  • Incorrect ouput of drives and PCI devices movement history in the Warehouse module was fixed.
  • Fixed the display of the server platform in the list of all equipment in the Warehouse module.
  • Fixed the error that appeared when trying to change a note for devices in the equipment lists in the "Warehouse" module.
  • Fixed the error that appeared when entering the "Warehouse" module if there was no equipment in the warehouse.

Version 6.10.3 03.02.2021

Bug fixes:

  • Fixed the error that occurred when launching operations and caused servers to disappear from the interface

Version 6.10.2 02.02.2021

Bug fixes:

  • Fixed an installer error that made it impossible to update DCImanager.

Version 6.10.1 02.02.2021

Bug fixes:

  • Fixed the problem where IPMI proxying would not work due to a busy VNC port.

Version 6.10.0 02.02.2021

New features:

  • Added the "Warehouse" module. The module supports inventorying of servers and their components. Added the ability to create types of equipment for CPUs, drives, RAM and PCI-e devices.
  • Added the possibility to specify NS servers in the "PowerDNS integration" module.
  • Added the ability to place servers into VLANs on release.

Improvements:

  • Messages about checking local connection speed, presence and detection of IPMI on the server were added to the information about server diagnostics.
  • Switch port mode "Duplex" was renamed to "Full-duplex".
  • The speeds in the switch ports list are now displayed clearer.
  • Added confirmation to remove addresses from the pool.

Bug fixes:

  • Fixed display of server status in the drop-down list of servers table.
  • Fixed checking of SSH key before installing the operating system on the server.

Version 6.9.1 26.01.2021

Improvements:

  • Added a description to the template for downloading ISO images in the English interface.
  • The "Operation templates" tab has been renamed to "OS templates".

Bug fixes:

  • Fixed an error in the display of OS template access settings in the English interface.
  • Fixed a rare error in the switch port list related to aggregations.

Version 6.9.0 19.01.2021

New features:

  • Added the ability to change the level of OS templates access permissions.

Improvements:

  • The IPMI password generation mechanism has been improved.
  • In the table of servers, the displaying of status of the blocked server with a running operation has been improved. Now the blocked status is displayed as an icon with a tooltip.
  • Fixed context loss in the "Select rack IP pool" modal window after changing general pool settings in a separate window.

Bug fixes:

  • The error of server deletion was fixed. The error occurred if deleting the server's IPs took longer than expected.

Version 6.8.0 22.12.2020

New features:

  • Added the ability to specify a note to the physical network.

Bug fixes:

  • Fixed the error in the "Server auto-adding" module configuration that occurred if only public networks were available in the platform.

Version 6.7.0 15.12.2020

New features:

  • Added support of DELL Force10 (S-series) switches.
  • Added support of HP switches.

Bug fixes:

  • Fixed the error that appeared in the list of IP addresses if the server did not have a primary IPv4 address.
  • Fixed the error in the form for adding the server that occurred if the platform's first IP address pool had only IPv6 addresses.

Version 6.6.1 08.12.2020

Bug fixes:

  • Fixed the display of the number of automatically found servers when a server is deleted or put into operation.
  • Fixed the problem with server rebooting via APC PDU, when some servers did not have enough time to shut down before the handler tried to power them on.

Version 6.6.0 01.12.2020

New features:

  • Added support of MikroTik CRS3XX switches.

Bug fixes:

  • The operation of group deletion of servers from a user account has been hidden.
  • Fixed the problem with erroneous notification about platform update.
  • Fixed the problem of receiving the information about serial numbers of the drives when selecting the OS installation parameters.
  • Fixed the problem due to which IPMI proxying could fail to function in case of task freezing.

Version 6.5.0 25.11.2020

Bug fixes:

  • Fixed the error of incorrect IPMI Proxy module operation on old IPMI firmware, which appeared due to inability to open old browser version.

Version 6.4.0 24.11.2020

New features:

  • Added the ability to lock and unlock the server. When a server is locked, all its connections to switches are disconnected.

Improvements:

  • Added the ability to load IPMI Supermicro X8 console.
  • Added sections "Improvements" and "Critical changes" to the list of platform changes.
  • Added the possibility to mark a physical network and a pool as public when creating them in the server card.

Bug fixes:

  • Fixed the display of the main menu items in the platform header when the browser window size was reduced.
  • Fixed the display of links in the list of platform changes.
  • Fixed the error that allowed to open the operation templates loading page if the location was not configured.
  • Fixed the display of server power status.
  • Fixed the problem with redirection after the platform update. The administrator could still have the update screen even after the update is completed.
  • Fixed the problem with displaying data confirmation window on server settings page. The window appeared when switching to another tab in the server card, if an operation was started and data were not changed.

Version 6.3.0 17.11.2020

New features:

  • Added the ability to allocate an IP address from the pool for IPMI during server diagnostics.
  • Added the ability to create server platforms with size over 2U.

Improvements:

  • Fixed the problem that could cause IPMI status to appear as "Not defined" after server reboot.

Bug fixes:

  • Fixed the problem with loading ISO images at URLs with redirecting.
  • Fixed the error that prevented periodic IPMI polling from functioning correctly.
  • Fixed the problem with IPMI proxying that occured when there were special characters in the user password.
  • Unsupported server auto-addition templates have been excluded.
  • Fixed incorrect check of operation availability when trying to restart.
  • Fixed deletion of templates and ISO images, operations with which were completed with an error.

Version 6.2.0 10.11.2020

New features:

  • Added the ability to manually allocate IP addresses in the physical network card.
  • Added the list of allocated IP addresses in the physical network card

Improvements:

  • Technical support contacts have been changed

Bug fixes:

  • Fixed the problem of displaying the data confirmation window on the page of server settings. The window would appear when switching to another tab in the server card, if the data were not changed.
  • Fixed display of a long comment in the server table
  • Fixed the error that prevented installation of the OS occurring on request of the server disk's serial number
  • Fixed the error due to which VLAN creation button was duplicated

Version 6.1.0 03.11.2020

New features:

  • Added support of Cisco Catalyst 45xx
  • Added the ability to connect ISO images when editing IPMI Proxy module settings

Improvements:

  • Fixed problems with editing VLAN on Juniper switches with ELS support
  • Added the ability to download Intel BMC IPMI console
  • Added the ability to load IPMI Asus console

Bug fixes:

  • Fixed the problem with SSL operation that appeared when polling Arista switches
  • Changed the format of information output from IPMI sensors
  • Fixed errors that could occur due to inability to connect to the location server via SSH
  • Fixed the error of incorrect disk space calculation during manual partitioning ("Server" -> "Install OS from template").
  • Fixed the error that did not allow starting OS installation with automatic disk partitioning
  • Fixed the error that did not allow updating the list of IPMI users
  • Fixed the error that did not allow working with the list of IPMI users after applying filters

Version 6.0.1 28.10.2020

Bug fixes:

  • Fixed the problem in the work of server auto-addition module

Version 6.0.0 27.10.2020

New features:

  • Added display of error status in the list of switches
  • Added the possibility to specify root partition size in disk partitioning manually ("Server" -> "OS Installation").
  • Added the "IPMI" section to the server page
  • Added the ability to manage IPMI users from the server page
  • Added the ability to view IPMI logs from the server page
  • Added the ability to view data from IPMI sensors from the server page

Bug fixes:

  • Fixed the error that prevented completion of the operation at the "Preparation" stage

Version 5.0.0 20.10.2020

Improvements:

  • Added the ability to load IPMI HP iLO5 console
  • Cisco Nexus switches will now be able to work with a self-signed SSL certificate
  • Juniper handlers have been optimized to make polling and other operations faster.

Bug fixes:

  • Fixed errors that could occur when polling a Cisco Nexus switch

Version 4.21.0 13.10.2020

New features:

  • Added the possibility to create a backup of the platform through the installer

Bug fixes:

  • Fixed the problem with calculating the number of busy switch ports
  • Fixed the problem with absence of ISPsystem contact information (email and phone)
  • Fixed the problem with IPMI password screening
  • Fixed the problem of deleting locations with ISO images

Version 4.20.0 06.10.2020

New features:

  • Added the history of actions with IP addresses of the physical network
  • Added support of scripts for installing Windows operating system
  • Added group operations to the table of servers and scripts
  • Added the ability to assign a VLAN for user

Improvements:

  • Added the option that allows you to manage the server only with PDU devices

Bug fixes:

  • Fixed the problem that prevented servers from receiving an IP address after rebooting during Windows installation
  • Fixed the error of data loading in tables

Version 4.19.1 29.09.2020

Bug fixes:

  • Fixed the display of tooltips in the control panel interface
  • Fixed incorrect operation of Cisco Nexus handler

Version 4.19.0 22.09.2020

New features:

  • Added port aggregation management feature for Arista and Cisco Nexus switches

Improvements:

  • JSON information added to modal error display window at the location

Bug fixes:

  • Fixed menu items overlapping in the header when reducing the window size
  • Fixed the problem where an IPMI session was unable to close

Version 4.18.0 15.09.2020

New features:

  • Added the possibility of automatic VLAN creation on several switches simultaneously.

Bug fixes:

  • Fixed the error that occurred when starting OS installation from an ISO image on the server.

Version 4.17.0 08.09.2020

New features:

  • Added the ability to run scripts for configuring the required environment after installation of the operating system. You can manage the list of scripts in the "Templates" section.

Improvements:

  • Added the ability to filter servers by host, owner, rack and chassis.

Version 4.15.0 25.08.2020

New features:

  • Added the ability to partition disks when installing the operating system

Improvements:

  • Added filtering of server table by configuration and platform
  • Added the ability to download IPMI Dell iDRAC 8 console

Bug fixes:

  • Fixed validation errors on the first location creation form
  • Fixed incorrect operation of the Juniper Junos 12 (NetConf) handler.

Version 4.14.1 21.08.2020

Bug fixes:

  • Fixed the error which occurred when deleting a server

Version 4.14.0 18.08.2020

New features:

  • Added display of server drive errors in "Server" -> "Accessories".
  • Added proxy support for Intel AMT

Improvements:

  • Added the ability to open multiple IPMI proxy windows to different devices

Version 4.13.0 11.08.2020

New features:

  • Added the ability to change the server rack and unit, PDU and switches
  • Added component tables to the server page
  • Added the ability to create public networks and pools
  • Added timeout for operations with server

Bug fixes:

  • Improved Juniper switch support for the EX4200 model

Version 4.12.0 04.08.2020

Improvements:

  • Added the ability to download IPMI HP iLO3 console
  • Added buttons for automatic filling of login and password in IPMI proxy

Bug fixes:

  • Fixed the error with launching operations if the server is running via IntelAMT
  • Fixed the problem with access to mail settings under admin's account

Version 4.11.0 28.07.2020

New features:

  • Added Intel AMT support

Version 4.10.0 21.07.2020

New features:

  • Added support of Juniper Junos 12 switches
  • Added saving of filtering and sorting parameters in the server list
  • Added the possibility to create user OS template on the basis of ISPsystem template
  • Added the possibility to connect the mail server for password recovery

Improvements:

  • Authorization procedure has been changed: now email and password fields are on the same form

Bug fixes:

  • Fixed the error display for unauthorized user

Version 4.9.0 14.07.2020

New features:

  • Added support of Cisco Nexus (NX-API) switches
  • Added the ability to update the list of available DHCP interfaces and nginx addresses in modal windows of location configuration
  • Added the abillity to run diagnostics on the server after the change of its owner
  • Added the link to documentation to the platform header

Bug fixes:

  • Fixed the display of date in "Server" -> "History" section.

Version 4.8.0 07.07.2020

New features:

  • Added the ability to check server power status and the possibility to power the server on/off if IPMI and/or PDU is available
  • Unblocked the server statistics for users
  • Added support of Arista switches

Improvements:

Version 4.7.0 30.06.2020

Breaking changes:

  • Disabled automatic start of diagnostics after release of server. Diagnostics is started from the billing system's side. Update BILLmanager or the WHMCS plugin to the latest version to use this functionality.

New features:

  • Added the server history section
  • Added the ability to assign IPv4 and IPv6 subnets to a server

Improvements:

  • Added the icon of IPMI connection to the switch

Bug fixes:

  • Fixed the bug with SMART disk check for errors

Version 4.6.0 23.06.2020

New features:

  • Added the ability to edit rack size
  • Added the ability to install vertically positioned PDUs in racks

Version 4.5.1 17.06.2020

Improvements:

  • Improved operation of Juniper ELS processing module

Bug fixes:

  • Fixed the problem with ordering a server from BILLmanager
  • Fixed the problem of server release with the Diag6 template
  • Fixed the problem with generation of IPMI password

Version 4.5.0 16.06.2020

New features:

  • Added the "Components" section to the server page

Version 4.4.0 09.06.2020

New features:

  • Added the column with the pool type in the "Network" -> "IP Pools" section
  • Added display of burstable data in server statistics
  • Added the ability to view server statistics for a specific port
  • Added the ability to use a single address space between DCImanager and VMmanager (modules -> "Integration with IPmanager 6").
  • Added the possibility to mark a server connection as IPMI connection

Bug fixes:

  • Removed the possibility to assign a switch port as trunk port without specifying trunk members
  • Fixed the error of wrong date format in the template table for Safari web browser

Version 4.3.1 03.06.2020

Bug fixes:

  • Fixed display of the notification about a new platform version available after its upgrade to the latest available version

Version 4.3.0 02.06.2020

New features:

  • Added display of pool at the rack on the pool adding and editing forms
  • Added support of ISO images
  • Added support of Juniper ELS switches

Improvements:

  • Added the template loading progress bar
  • Added support display for EFI template

Bug fixes:

  • Fixed the error of displaying the date of the last update in the templates table

Version 4.2.0 26.05.2020

Bug fixes:

  • Fixed the error of displaying active Trunk members on the switch port configuration form

Version 4.1.2 19.05.2020

Improvements:

  • Improved the work of HTTP service at location

Bug fixes:

  • Fixed the error in SMART disk analysis, which prevented completion of diagnostics

Version 4.1.1 19.05.2020

Bug fixes:

  • Fixed the error of editing the server's IP address, when an operation is running on the server
  • Fixed the display of the list of loaded templates in the "Location configuration" modal window when no active location is configured
  • Fixed the display of validation message when adding racks
  • Fixed incorrect display of the rack and unit number in device editing forms

Version 4.1.0 12.05.2020

New features:

  • Added local connection speed measurement for diagnostics
  • Added automatic detection of available RAIDs on the OS installation form

Improvements:

  • Added the ability to download Cisco IPMI console

Bug fixes:

  • Fixed the error when switching to IPMI interface through proxying

Version 4.0.0 06.05.2020

Breaking changes:

  • Changes were made in the operation of internal services

New features:

  • Added integration with the PowerDNS domain name server to manage reverse records

Version 3.4.0 28.04.2020

New features:

  • Added support of IPv6 addresses
  • Added the possibility to work with old types of IPMI via the web interface

Version 3.3.0 21.04.2020

New features:

  • Added the option to select software RAID 0, 1, 5, 10 configuration when installing the OS on the server
  • Added the possibility to select the platform when adding or editing a server
  • Added the ability to manage OS templates, diagnostics and recovery at the active location in "Templates" section
  • Added the possibility to manage server platforms in section "Equipment" -> "Equipment types".

Bug fixes:

  • Fixed display of IP address status when it is allocated to a server at the server page
  • Added check whether IP pool name is correct, when it is being edited
  • Fixed the behavior when removing a server from the server table

Version 3.2.0 14.04.2020

Bug fixes:

  • Fixed the error when editing the connection parameters for free port of the switch

Version 3.1.0 07.04.2020

New features:

  • Added the ability to disable traffic gathering on the switch port
  • Added the possibility to assign "Service" and "UpLink" modes to switch ports
  • Added the ability to specify IP address pools for server release and provisioning
  • Added the ability to assign IP address pools to racks

Bug fixes:

  • Blocked the ability to enable/disable the switch port if it is already in the process of being enabled/disabled
  • Fixed display of IP address pools for which no physical network is created

Version 3.0.2 31.03.2020

Bug fixes:

  • Fixed problems with VLAN for "SNMP Common" and "Juniper (NetConf) JunOS 15" switch types.

Version 3.0.1 24.03.2020

Bug fixes:

  • Fixed the problem with configuring trunk ports on Cisco switches

Version 3.0.0 24.03.2020

Breaking changes:

  • Changes were made in the work of internal services

New features:

  • Added the ability to work with virtual networks (VLAN)

Bug fixes:

  • Fixed switch type names
  • Fixed the error with opening a proxy session that occurred on some types of IPMI

Version 2.0.0 17.03.2020

Breaking changes:

  • Changed API for interaction with the notifications mechanism

New features:

  • Implemented protection against CSRF/XSRF attacks

Bug fixes:

  • Added the ability to use domain name as a URL for IPMI

Version 1.11.0 11.03.2020

New features:

  • Added the possibility to enter IPMI console (for Supermicro servers)
  • Added the possibility to update information about license

Bug fixes:

  • Fixed the error, which prevented user from launching server recovery
  • Added validation of fields in the server editing form
  • Added validation of fields in the server adding form
  • Fixed the problem with display of messages about equipment access error in the list of server connections and user interface
  • Added automatic IPMI configuration when performing diagnostics after server release

Version 1.10.2 04.03.2020

Bug fixes:

  • Fixed the problem with ports validation when collecting statistics

Version 1.10.1 26.02.2020

Bug fixes:

  • Added ability to redefine template macros via API

Version 1.10.0 25.02.2020

New features:

  • Added support of Juniper switches

Version 1.9.0 25.02.2020

New features:

  • Added possibility to specify the owner when adding the server
  • Added connections section in server page

Version 1.7.0 18.02.2020

New features:

  • Added the ability to remove chassis in the server adding form
  • Added the ability to edit physical network
  • Added the section of IP addresses on server page

Bug fixes:

  • Fixed the problem of editing IP address pools in the table "IP address pools" of the "Network" menu item

Version 1.6.0 11.02.2020

New features:

  • Added the ability to edit switch and power distributor (PDU)
  • Added display of errors found during server diagnostics

Bug fixes:

  • Fixed the error when settings in server dashboard of user interface were unavailable

Version 1.5.1 04.02.2020

Bug fixes:

  • Fixed the error of adding a server in absence of a rack

Version 1.5.0 04.02.2020

New features:

  • Added support of racks and blade servers
  • Added the possibility to manage access of technical support to the panel in section "Settings" -> "System Overview".

Bug fixes:

  • Changed navigation of transitions from servers table to server dashboard

Version 1.4.1 29.01.2020

Bug fixes:

  • Fixed problem with aggregation of statistics

Version 1.4.0 28.01.2020

New features:

  • Added the ability to install Windows OS templates on servers
  • Server recovery mode has been implemented
  • Added the ability to install Windows OS on the server
  • Added display of the number of errors detected during diagnostics
  • Added the ability to configure IPMI during diagnostics

Bug fixes:

  • Blocked allocation of IP address to the server while any operation is running
  • Fixed the error of being able to run diagnostics and OS installation while loading or uninstalling the template from the location
  • The user section has been moved to the main menu
  • Adding IP pools, physical networks and devices is blocked if the active location has the status "Setup in progress" or "No connection".
  • Fixed owner selection in server settings

Version 1.3.0 21.01.2020

New features:

  • New design of product page top was implemented

Bug fixes:

  • Fixed bug allowing to launch server diagnostics operation with the diagnostics template being deleted or loaded
  • Fixed bug with adding SNMP v3 switches

Version 1.2.0 14.01.2020

New features:

  • Troubleshooting errors analysis feature added

Bug fixes:

  • Errors in server traffic statistics calculation corrected

Version 1.1.0 24.12.2019

New features:

  • Main IP address change feature added to server dashboard Settings
  • Added filters and sorting options in tables
  • Added IPMI edit function
  • Added edit location function.
  • Traffic statistics section added to server card
  • Server owner change feature added to server dashboard Settings

Bug fixes:

  • The control panel now displays servers that are blocked for a user
  • A new notification informs all users that the control panel update has been started

Version 1.0.0 17.12.2019

New features:

  • Added user interface
  • It is now possible to create a user with the "User" access level

Bug fixes:

  • Control panel version in "Settings" -> "System overview" was defined incorrectly
  • Fixed license expiration date in "Settings" -> "System overview"
  • Fixed status bar in servers list
  • Fixed menu on the IP pool card
  • Modified user avatar

Version 0.8.0 10.12.2019

New features:

  • DCImanager can be integrated with the billing system WHMCS
  • Added clear disk function by server owner

Bug fixes:

  • Improved stability of IPMI Proxy v2 module: fixed rare bugs that caused browser to hang and bugs related to opening and breaking of sessions

Version 0.7.0 03.12.2019

New features:

  • Added a new section "System overview" in the "Settings" menu
  • It is now possible to update DCImanager: when a new version is released, the corresponding notification is displayed in the control panel; the panel can be updated from the "System overview" section in the "Settings" menu
  • New section "Users" added to "Settings" menu. You can now create a control panel administrator
  • Changelog added to "System overview" section in "Settings" menu

Bug fixes:

  • Fixed bug that occurred when scrolling pages on switch and PDU cards
  • If the new version notification was closed, it won't be displayed until a new version is released
  • Fixed service duplication bug

Version 0.6.0 26.11.2019

New features:

  • The system now checks domain name server records and adds them if needed during location configuration.

Version 0.5.2 22.11.2019

Bug fixes:

  • Fixed the bug that occurred when checking an operating system before deployment

Version 0.5.1 20.11.2019

Bug fixes:

  • Fixed a number of location creation bugs

Version 0.5.0 19.11.2019

New features:

  • Added a new status in the switch card that displays the switch poll
  • Added a new warning that informs about an invalid IP address when trying to run an operation
  • It is now possible to assign a new IP address to the server from the modal window with the IP allocation error message
  • Errors will be displayed in a modal window in the "Servers" table
  • New server status: "Allocating IP address"
  • Equipment management logics was moved to a separate container to reduce load on the container with DCImanager. It will also help add custom handlers easily and scale up the equipment service in the feature.
  • Added a new status in the list of ports that displays changes of the switch port

Version 0.4.0 12.11.2019

New features:

  • New notification informs users about missing templates during OS deployment
  • Added a new status that informs about changes of the switch port settings

Version 0.3.0 05.11.2019

New features:

  • Added server cards with settings

Bug fixes:

  • The number of racks in the racks table is now calculated correctly

Version 0.2.0 29.10.2019

New features:

  • Introduced support of ipxe for diagnostics template

Bug fixes:

  • Fixed the bug that occurred when starting a container with the http-server after the location server reboot
  • Fixed the server deletion bug that occurred if devices were connected to the server

Version 0.1.1 22.10.2019

Bug fixes:

  • Fixed the bug that occurred when running operations with templates that require updates

Version 0.0.3 18.10.2019

Bug fixes:

  • Fixed the bug: sometimes it was not possible to receive a list of OS templates.
Show more