You can set up notifications to platform administrators about the status of equipment. Notifications are sent:

  • in pop-up windows;
  • in the servers table in the Status column;
  • to administrators' emails.

If a notification is created for the server, the server status will change to "Error".

The range of available notifications depends on the installed modules and hardware models.

Work logic

The following types of notifications can be set up in DCImanager 6:

ObjectNotification type
Serversone or several errors have been found during diagnostics

view faults and critical component status (DCImanager 6 Infrastructure licenses only) 

Notifications about component problems are created only for servers with BMC Redfish and devices that transmit their health status.

BMC sensors

voltage out of range

temperature out of range

fan speed out of range

Equipment warranty

equipment warranty is expired

Equipment reservation

equipment reservation is expired

Storage monitoring - main events

















Controllers Health status does not match the expected state
Status does not match the expected state
IOPS out of range
Read speed out of range
Write speed out of range
CPU utilization out of range
Drives Health status does not match the expected state
Status does not match the expected state
Disk groups Health status does not match the expected state
Status does not match the expected state
IOPS out of range
Read speed out of range
Write speed out of range
CPU utilization out of range
Pools Health status does not match the expected state
Volumes Health status does not match the expected state
Status does not match the expected state
IOPS out of range
Read speed out of range
Write speed out of range
CPU utilization out of range
Disk shelves Health status does not match the expected state
Status does not match the expected state
Power supplies Health status does not match the expected state
Status does not match the expected state
Fans Health status does not match the expected state
Status does not match the expected state
System Health status does not match the expected state
Status does not match the expected state
Ports Host health status does not match the expected state
Host status does not match the expected state
Management health status does not match the expected state

Storage monitoring - user events

Initially, this section is empty. You can add your own events here.

BMC sensors notifications

In the notification settings, you set the period of time after which the parameter out of the range is considered critical. The maximum and minimum allowable parameter values are set in the server BMC.

DCImanager 6 periodically polls BMC every five minutes. If the parameter value is out of range, the platform will poll BMC again after the time interval specified in the notification settings. If the parameter value does not return to acceptable values, DCImanager 6 will create a notification. No repeat notifications about this event will be created in the platform.

If the parameter value was out of range for a given time and then returned to normal, DCImanager 6 will create a notification about it.

For example, the platform administrator has configured a setting for the "Temperature out of range for 2 minutes" notification. DCImanager 6 polled the BMC at 12:00 and found the temperature to be higher than normal. In this case, the platform will poll the BMC at 12:02 and, if the temperature remains outside the range, an appropriate notification will be created. DCImanager 6 will continue to poll the BMC every five minutes and, if the temperature drops to an acceptable value, it will create a "Temperature back to normal" notification.

Managing notifications

To configure notifications, enter Notification center:  Notification settings.

How to open the notification center
How to open the notification center


Notification center interface
Notification center interface

Creating notification settings

To create settings for a notification:

  1. Click Configure new notifications .
  2. Configure the settings for BMC Servers and sensors:
    1. To customize notifications for specific locations or servers, click change and select the required settings.
    2. Select events for notifications. A separate setting will be created for each event.
  3. Configure the settings for Warranty and reservation:
    1. To customize notifications for specific warehouses, equipment categories, and units, click change and select the required settings.
    2. Select events for notifications. A separate setting will be created for each event.
  4. If you use the Storage module, configure the settings for Storage monitoring:

    1. To set up notifications for specific storage system components, click e dit and select the required parameters.
    2. Select events for notifications. A separate setting will be created for each event.
    3. To configure custom events, open the dropdown section Storage monitoring - user events, click Add event, and specify the desired settings.
    The MetricsQL language is used to create user events. See more in the VictoriaMetrics documentation and the documentation of the storage hardware vendor.
  5. Select the admins' emails to which notifications will be sent.
  6. Select Telegram chats in the  To the messengers' channels  field.  For more information about channels, see the article Sending notifications to Telegram.
  7. Click Create notifications .
Form for creating notification settings
Form for creating notification settings

Actions with notification settings

To enable/disable the created settings, click  in the settings line.

To delete settings, click the following in the settings line:   Delete .

To edit settings, click the following in the settings line:   Edit.

To view the notifications generated by DCImanager 6, enter  All notifications .