DCImanager 6
en En
es Es

Equipment reports

You can generate a report with information about the equipment added to the platform:

  • main equipment systems;
  • server firmware;
  • server hardware;
  • used rack units;
  • information about individual table fields.

You can also create a template for your own reports.

Built-in reports are exported in CSV format, custom ones — in CSV or TXT format.

Report types

By default, the platform provides the following reports:

Name

Content

Basic Systems Report — Chassis

Information about chassis main systems: name, platform, serial number, chassis location, number of occupied and free slots.

Basic Systems Report — PDU

Information about PDU main systems: name, model, serial number, IP address, PDU location, number of ports.

Basic Systems Report — Server

Information about server main systems: name, platform, serial number, server location, IP address and BMC URL

Basic Systems Report — Switch

Information about switch main systems: name, platform, serial number, IP address and switch location, number of Ethernet and FC ports.

Basic Systems Report — UPS

Information about UPS main systems: name, model, serial number, IP address and UPS location.

Firmware Report — Server

Information about server firmware: server name, platform and serial number, BMC URL, component name, location and firmware version.

Hardware Inventory Report — Server

Information about server hardware: name, platform, serial number, server location, BMC URL, CPU model, RAM size, network adapters, PCIe devices, BIOS and BMC firmware versions.

Units Usage Report — Rack

Information about used rack units.

Visible Fields Report — Chassis

Information about fields selected in the chassis table.

Visible Fields Report — PDU

Information about fields selected in the PDU table.

Visible Fields Report — Rack

Information about fields selected in the racks table.

Visible Fields Report — Server

Information about fields selected in the servers table.

Visible Fields Report — Switch

Information about fields selected in the switches table.

Visible Fields Report — UPS

Information about fields selected in the UPS table.


Server models are available only for BMC Redfish.

Serial numbers are added to the report only if the "Inventory management" module is installed in the platform.

Preparing a user template

To create a user template:

  1. Go to the Reports section: in the right menu, click the icon.
  2. To create a template from scratch, click the Create a template button.
  3. To create a template based on an existing one:
    1. In the row with the template, click the icon → Duplicate.
    2. Click the name of the created template.
  4. Specify the template parameters:
    1. Name.
    2. Any Comment.
    3. Data sources:
      1. Data array name, which provides access in the Jinja template.
      2. URL from which the platform retrieves data — an endpoint in the format <service_name>/<api_version>/<endpoint>.
      3. Object assembly key — an optional parameter.
        To add a source, click the Add a source button. To remove a source, click the icon in the source row.
    4. Template in Jinja format. To check the template for correctness, click the Check button. In the Check result block, the report content or an error message will be displayed.
    5. File type — TXT or CSV.
  5. Click the Create (Save) button.

To delete a user template, in the row with the template, click the icon → Delete.

Example template

For example, to create a report on servers:

  1. In the Data array name field, specify: servers
  2. In the URL field, specify: dci/v3/server
  3. In the Template field, enter:
    {{ caption("server_id") }},{{ caption("name") }}
    {% for server in servers -%}
    {{ get(server, "id") }},{{ get(server, "name") }}
    {% endfor -%}

Report creation

You can generate a report:

  • from the Reports section — for all locations;
  • from equipment tables using bulk actions — for the current location;
  • from a device card — for a specific device;
  • from a rack card — for all devices in the rack, if the "Rack visualization module" is installed in the platform.

Reports section

To open the section, click the icon in the right menu . To generate a report:

  1. On the Templates tab, click the icon in the row with the required template .
  2. Wait for the The report has been generated notification and click the icon in the template row .


Section interface
Section interface

Equipment table

  1. Go to the required equipment section: Servers, Chassis, Switches, Power distribution unit (PDU) or UPS.
  2. Select the required devices. If no device is selected, the report will be generated for all devices in the current location.
  3. If you need to generate a report for selected columns, click the icon in the table header and select the required columns.
  4. Click Generate report and select the report type.
  5. When the report is ready, a pop-up notification The report has been generated will appear in the platform. Click the Download as CSV link in it. You can also download the report later in the Reports section → History tab.

Server card

  1. Go to the server card: Servers → select the required server → click Server parameters.
  2. Go to the Reports tab.
  3. In the block with the required report, click Generate report.
  4. When the report is ready, a pop-up notification The report has been generated will appear in the platform. Click the Download as CSV link in it. You can also download the report later in the Reports section → History tab.

Rack card

  1. Go to the rack card: Racks → select the required rack.
  2. In the right part of the window, click the required report type.
  3. When the report is ready, a pop-up notification The report has been generated will appear in the platform. Click the Download as CSV link in it. You can also download the report later in the Reports section → History tab.

Report history

To manage report history, in the right menu, click the icon → the History tab. The tab is active if at least one report is saved in the platform.

To open the report history for a template, click the icon in its row on the Templates tab.

Report management is performed via the menu . Possible actions:

  • Information — display information about the report template;
  • Download — save the report file. The operation can also be performed via the icon in the row with the report;
  • Delete — delete the report file.